Podrobnosti záznamu

Název
    Ultrasonic Determination of Porosity in Homogeneous Ceramic Samples
Autor
    Eskelinen, J.
    Haeggström, E.
    Hortling, A.
    Karlqvist, R.
    Kohout, Tomáš
    Lassila, I.
    Pesonen, L. J.
Jazyk
    anglicky
Typ dokumentu
    článek v odborném periodiku
Zdrojový dokument - seriál
    Geophysica
Svazek/č.
    Roč. 49, 1/2
Strany
    s. 25-32
Rok
    2013
Poznámky
    Rozsah: 8 s. : E
Předmětová kategorie
    longitudinal wave
    porosity
    pycnometry
    shear wave
    ultrasound
Klíčové slovo
    Ceramic
    Determination
    Homogeneous
    Porosity
    Samples
    Ultrasonic
Abstrakt (anglicky)
   An ultrasonic method was tested to rapidly determine the porosity in custom made ceramic samples. The samples with porosities between 4 and 33% were of identical composition. The porosity estimates by ultrasonic method were validated against those obtained by helium and air pycnometry as well as with Archimedean method. The ultrasonic measurements can be performed rapidly (less than a minute) but they require a well prepared sample.
Přispěvatel
    AV ČR Brno, Geologický ústav
Kód přispěvatele
    AV ČR, GLÚ
Zdrojový formát
    U
Datum importu
    23. 10. 2014